CDA Home
 
   
Ground Combat Training Systems
 

Field Maintenance Reports:


AT4 SIMULATOR ASSEMBLY
DRAWING 147751 SITE REWORK



Click on the thumbnail to enlarge
Click to enlarge photo
2. Using syringe, apply RTV
in the Sight Channel along
the right front side of Sight.
Make certain that Sight
channel is filled with RTV.
Click to enlarge photo
3. Using syringe, apply RTV
in the Sight channel along
the left front side of Sight.
Make certain that Sight
channel is filled with RTV.

4. Using syringe, apply RTV
in the Sight channel along
the bottom front of Sight.
Make certain that Sight
channel is filled with RTV.
5. Allow RTV applied to
front of Sight to dry for
approximately five (5)
minutes before proceeding.

6. Using syringe, apply RTV
in the Sight channel along
the right rear side of Sight.
Make certain that Sight
channel is filled with RTV.
Click to enlarge photo
7. Using syringe, apply RTV
in the Sight Channel along
the left side of Sight. Make
certain that Sight channel
is filled with RTV.
Click to enlarge photo
8. Using syringe, apply RTV
in the Sight channel along
the bottom rear side of Sight.
Make certain that Sight
channel is filled with RTV.
Click to enlarge photo
9. Allow RTV applied to
front of Sight to dry for
approximately five (5)
minutes before proceeding.
Click to enlarge photo
10. Remove excess RTV
from top edge of front and
rear sight. Air cure for 72
hours.
     
 
Corporate Home | CDA Home | Products & Services | Newsroom | Contact Us | Search | Top

Copyright © 2004 ALL RIGHTS RESERVED Cubic Corporation